Can you go to All Programs -> SolarWinds Orion -> Documentation and Support -> Log Adjuster, and click Reset to Default.
Set all the logging back to default.
- Upgrade your NPM and Modules so you do not have such issue in feature. /
- Alternatively use the remedy action below.
Here's the remedy action:
1) Do a backup copy of the 2 files SolarWinds.NPM.BusinessLayer.dll.config and SolarWinds.Orion.Core.BusinessLayer.dll.config
2) Stop all Orion Services using the Service Manager
3) delete WHOLE "system.diagnostics" part from SolarWinds.NPM.BusinessLayer.dll.config and SolarWinds.Orion.Core.BusinessLayer.dll.config. Examples of the section as below.
4) And after that restart all services and delete mentioned log files.
System.diagnostics part:
<system.diagnostics>
<sources>
<source name="System.ServiceModel" switchValue="Off,ActivityTracing" propagateActivity="true">
<listeners>
<add type="System.Diagnostics.DefaultTraceListener" name="Default">
<filter type=""/>
</add>
<add name="ServiceModelTraceListener">
<filter type=""/>
</add>
</listeners>
</source>
<source name="System.ServiceModel.MessageLogging" switchValue="Verbose,ActivityTracing">
<listeners>
<add type="System.Diagnostics.DefaultTraceListener" name="Default">
<filter type=""/>
</add>
<add name="ServiceModelMessageLoggingListener">
<filter type=""/>
</add>
</listeners>
</source>
</sources>
<sharedListeners>
<add initializeData="c:\temp\Core_BusinessLayerPlugin_tracelog.svclog" type="System.Diagnostics.XmlWriterTraceListener, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" name="ServiceModelTraceListener" traceOutputOptions="Timestamp">
<filter type=""/>
</add>
<add initializeData="c:\temp\Core_BusinessLayerPlugin_messages.svlog" type="System.Diagnostics.XmlWriterTraceListener, System, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089" name="ServiceModelMessageLoggingListener" traceOutputOptions="Timestamp">
<filter type=""/>
</add>
</sharedListeners>
</system.diagnostics>